In stock
NIKON Research Polarizing Microscope Eclipse LV100N-Pol with with Heating Stage
Rp. 1.275.000.000
|
Type Brand Stock |
: : : |
Eclipse LV100N-Pol + Linkam MDS600 Nikon 2 Unit |
| Kategori | : | Alat Laboratorium |
| Tayang Mulai | : | - |
| Tayang Selesai | : | - |
| Link Produk | : | |
| Jenis Produk | : | import |
Optical system: CFI60 infinity system Illumination: 12V-50W halogen lamp; 12V-50W DC transformer built-in; Diascopic/episcopic illumination changeover switch; NCB11, ND8 filters built-in. Complete with fly eye lens that enables high quality digital imaging with no variations in luminescence throughout the view field. Focusing: Coaxial coarse/fine focus knob; Focus stroke: 30mm; Coarse: 14mm per rotation; Fine: 0.1mm; Minimum reading: in 1µm increments Eyepiece: 10x (F.O.V. 22mm), CM type with crosshair and micrometer scale Eyepiece tube: P-TT Trinocular Tube for polarizing microscopy Intermediate tube: Built-in focusable Bertrand lens removable from optical path; Conoscopic/Orthoscopic observations switchable; Analyzer built-in; Plate/compensator slot Analyzer: 360° rotatable; Minimum reading angle 0.1° Nosepiece: Reversed centering quintuple nosepiece (detachable); DIN slot Stage: Top-grade dedicated circular graduated stage, Rotatable 360°horizontally; Graduated 360°(in 1°increments), Mechanical stage attachable: 35 x 25 mm travel; vernier 0.1mm Click-stops in 45°increments Condenser: Dedicated strain-free swing-out type; Plan Achromat N.A. 0.9 Polarizer: Fixed to the bottom of the condenser holder; Scale Objectives: CFI TU Plan Fluor BD 5x/23.5, 10x/17.5, and Plan Epi SLWD 20x/30, 50x/22, 100x/10 Compensators: Standard 1/4λ & tint plate Power consumption: 1.2A/75W Heating Stage WIDE TEMPERATURE RANGE The temperature range spans from < -195°C (using the optional LNP96-S) up to 600°C (125°C for the MDBCS196), accommodating a versatile range of experimental conditions. The stage body is water-cooled for work above 300°C. RAPID HEATING /COOLING RATES The powerful T96-S controller allows the stage to heat samples at a maximum rate of 150°C/minute. MOTORISED XY MANIPULATION Control of sample position over 15mm of travel in X and Y directions via precision micro-stepped motors. Use software to set and control XY position (“go to position”) and movement speed. HIGH DEGREE OF ACCURACY AND STABILITY
| Type | Eclipse LV100N-Pol + Linkam MDS600 |
| Merek | Nikon |
| Nama Alat | NIKON Research Polarizing Microscope Eclipse LV100N-Pol with with Heating Stage |
| Sub - Kategori | Alat Uji |
| Kategori | Alat Laboratorium |
Related Products
More Products
ISQ EM LIQUID CHROMATOGRAPHY MASS SPECTROMETRY LCMS SINGLE QUADRUPOLE
EVOLUTION ONE SPECTROPHOTOMETER UV-VIS
FLASHSMART CHN ORGANIC ELEMENTAL ANALZYER WITH MICROBALANCE
Labverse Furnace 1200 C
Suntex Laboratory pH/mV/TEMP Meter
Accretech Hybrid Surface Roughness and Contour Tester
Suntex Conductivity Meter