Midi Plus Horizontal Electrophoresis System ME7-7-10 Specification: - Low buffer consumption of 0.06gal (225ml) - Single molded tank,
durable, leak proof environment for complete safety and long life - Easy sample loading - Multi-channel pipette compatibility - Great
indications for gel making and running - No tape, clamps or springs needed - Gel dimension: 2.8"x2.8" (70x70mm) and 2.8"x3.9" (70x100mm)
Maximum sample: 32 for 2.8"x2.8" (70x70mm) Tray (2x16 sample combs) and 64 for 2.8"x3.9" (70x100mm)Tray (4x16 sample combs)
Inexpensive cassette type electrode, easy to replace and made of 99.99% corrosion resistant pure platinum - Electrical safety: lid can only be
fastened in one way, upon lid removal, power is disconnected from buffer chamber - Rapid casting gel: use casting dams - A complete system
includes:1 x Electrophoresis tank & lid, 1 x ME7-UV7 (7x7cm UV tray), 1 x ME7-UV10 (7x10cm UV tray), 2 x ME7-8-1 (8 sample combs, 1mm
thick), 1 x ME7-UVDAM (UV tray dams, 2pcs), 1 x ME7-LG (Loading guides (Set)), 1 x Black & red electrophoresis cable. Lively 300V Power Supply
Specification: - Four pairs of output terminals - 2.4” TFT-LCD colored screen shows all parameters during operation - Timer with alarm function
Compact size with stackable case - Constant voltage/ current/ power operation mode - Typical Running condition helps electrophoresis
beginner - Wide application for DNA, RNA and protein electrophoresis and blotting - Advanced safety device design - Output Voltage / Inc: 5
300V / 1V, Output Current / Inc: 1 - 700mA / 1mA - Power: Input:200W; Output: 150W - Related voltage: 100-240V~; 47-60Hz - Type of output:
1. Voltage or Current with automatic crossover; 2. When target constant mode is set, system automatically adjusts the two other parameter
to maximum to allow constant run (later could be changed by user) - Program storage: 30 programmed files - Program multi-step: Up to 6
steps - Editable program function: 1.Typical running conditions program, 2.Manual editable program - Microprocessor controller - Safety
device: no Load detect, leakage detect, over temperature protection, over load detection, sudden load change detection (could be enabled by
proper setting), shrouded plugs and sockets - Timer: Constant: 9999 (min) with alarm/ Continuous; Program: 999 (min) with alarm/ Continuous
Crossover: yes; stackable: yes; automatic Recovery After Power Failure: yes - PC housing and flame retardant ABS faceplate material
Type | ME7-7-10 + MP-310 |
Merek | Majorscience |
Nama Alat | Midi Plus Horizontal Electrophoresis System ME7-7-10 and Lively 300V Power Supply |
Sub - Kategori | Alat Uji |
Kategori | Alat Laboratorium |